Switchgear is an electrical tool used to control the electricity flow into an electrical system. The devices and hidden equipment are used for the same purposes, to prevent overloads and short circuits and to de-energize circuits for testing and maintenance. Circuit breakers and fuses, which stop the power flow from getting too high, and power switches, which exchange electricity sources from primary to a secondary source, for example, access to power generation when power is shut down, are the most common types of switchgear.
The switch must serve as a transmission, formation, and division of the normal load current. Furthermore, the defect current must be visible, which depends on the application, is used for sensing devices such as current transformers, future transformers, and various types of relays. In addition, there must be calculation, control, and data, using innumerable devices for switching purposes.
It may include disconnectors, current transformers, potential transformers, measuring devices, switches, fuses, MCB’s, emergency arresters, isolators, and a variety of systems.
Features of Switchgear
Complete Reliability
The ongoing interconnection trend and rising capability of power plants have given priority to the need for reliable switchgear.
Unsurprisingly, the power system is added to increase reliability. If a fault occurs on any portion of the power grid, the faulted segment of the remaining circuit must be isolated.
Certain Discrimination
If any power system segment has a malfunction, the switchgear needs to be able to differentiate between the damaged section and the safe section.
The defective section should be isolated from the device without affecting the safe segment. This ensures the consistency of delivery.
Quick Functionality
If any aspect of the power system is defaulting, the switching equipment must be worked rapidly so that the short circuit current does not harm generators, transformers, or other equipment.
It can spread to safe sections if the fault is not removed rapidly, thereby endangering the complete system shutdown
Manual Monitoring Provisions
Manual control must be provided for switchgear by switchgear-manufacturing companies in UAE. In the event that the electric (or electronic) control fails, manual control may be used to perform the required operation.
How to Extend the Life of Your Switchgear
Aging switchgear can impact reliability and financial losses negatively on the continuity of services in industrial facilities.
In particular, the protection of workers may be affected. According to Contingency Planning Research, in addition to possible threats to human lives, downtime costs have now been measured in million dollars/hour.
The life span of the switchgear depends mainly on how massive the load is and how many switching cycles are there. The reference to the number of operations is typically made rather than a cycle with the electromechanical switchgear since the aging depends primarily on stress and less on the on and off phase between switching.
Following are some life extension tips to enhance electrical reliability.
Perform Infrared Inspections
Thermal imaging (infrared) is a helpful tool that can be performed while the equipment is energized, but not a replacement for a maintenance program. If performed safely and correctly, loose bus connections can be detected by infrared inspection until they result in a complete or partial outage of equipment. To fix the defined issue, maintenance can be arranged by switchgear-manufacturing companies in UAE. The installation of infrared viewing windows enables infrared inspections to be conducted easily and safely.
Exercise Circuit Breakers Annually
Manually operating circuit breakers once a year is a basic but very precious activity. This guarantees clean contacts and free flow of organizational mechanisms.
Do not ignore the recommended maintenance
Cleaning, inspections, tightening, lubricating and regular exercising of the switchgear are necessary. The Diesel generator suppliers in UAE determine the maintenance frequency by operating conditions. The isolation, conductive materials, and protective equipment shall be degraded at an accelerated pace with moisture and heat combined with dirt, dust, and other environmental contaminants.>
Recondition the Equipment
In-house retrofitting shall be a more intensive repair alternative for circuit breakers if on-site maintenance work does not permit the circuit breaker to comply with tolerances as specified by current industry standards. First, the circuit breaker is assessed against ANSI requirements and then disassembled, cleaned, and inspected completely. Damaged components are reworked or removed and pivot points are refurbished before the reassembly of the circuit interrupter. The reconditioned circuit breaker is checked against ANSI requirements, including the new assemblies.
Keep Strong Records and Pattern Performance
Where maintenance tests are not used to monitor circuit breaker efficiency, deterioration in isolation and moving components could become unknown. Without design tolerance, switchgear components can still be used for a long time. The tracking of test data provides a better picture of the life expectancy of equipment and contributes to the emphasis on repair areas.
Upgrade the Equipment
The developments in circuit breaker designs can no longer be viewed as sustainable alternatives for those with older technology. The switchgear lineup may be substituted to take advantage of advanced technologies. A cheaper option would be to keep the switchgear and bus structure in place and update the current equipment with the new state-of-the-art interrupters.
Outsource Preventive Maintenance Via a Long-Term Service Agreement
All of the required service activities for a distribution system can be carried out by very few electrical maintenance or contracting firms.
A professional electrical engineer may help plant management by selecting a qualified electrical maintenance contractor to establish a maintenance and frequency service agreement.
This means that maintenance is not neglected and uniform working areas are used for the entire period of the contract.
Use Predictive Tools for Maintenance
In order to prevent impending failures, online monitoring tools can also be provided in addition to tendency test data that can be analyzed for the provision of equipment life and maintenance needs.
Online monitoring systems of switchgear-manufacturing companies in UAE work constantly and benefit from the recognition of conditions unable to be observed during one-time inspections.
Perform a short circuit analysis and a time study
If there is no proper shortening rate for switchgear components, the equipment and the surrounding area could be catastrophically damaged. A short circuit analysis determines whether the switchgear is correctly rated. The teamwork analysis will also have to be revised. Coordinated circuit breaker settings can prevent the switchgear from unnecessary interruptions of defects, which a downstream device should have interrupted.
As an industry leader in electronics equipment such as circuit breakers, switchgear, motor controls, transformers, relays, and other electrical equipment, ATS Electrical Generator TR. LLC one of the leading switchgear-manufacturing companies in UAE has experienced tremendous growth. All our systems have been tested to OEM and industrial requirements. Our team of engineers and technicians is dedicated to providing high-quality products to customers.